How do I connect my instrument via my LAN to UltraSigma PC Software?
Last Updated: 23/12/2013
First of all, ensure your instrument as the option for LAN connection and ensure you have a PC running the latest version of UltraSigma download from RIGOL and this PC is successfully connected to the same local area network as you're plugging your instrument into.

In order for you to connect your Rigol equipment via LAN you must:

  1. Ensure your instrument is connected through the LAN socket - the lights are showing green for connection.
  2. Start up the UltraSigma program on your PC.
  3. Occasionally, the LAN(IP) address* that corresponds with the instrument has already appeared in the UltraSigma utility tree view, otherwise proceed:
  4. If this does not happen right away, press the LAN button on the UltraSigma program. Here you can manually enter its IP Address*, test and add the instrument.
  5. Your instrument should now be connected to Ultra-sigma and Model & Serial Number will show in the tree view. Now you can right-click this and perform checks:
    1. Try choosing SCPI Command Window - then click SendAndRead to see if the instrument responds to a *IDN? request (to identify itself).
    2. On some instruments you can also Print Screen directly to windows.
  6. *IF UNSURE your own LAN is set up to allow instrument connections:
    1. Check with your Network Admin - they may need to set up a DHCP server, so your LAN assigns the instrument an IP Address permitted by your LAN (most small LANs do this automatically but many corporate LANs only do this with permissions in place first).
    2. Go to your instrument front panel. Press button for System or Utility - you will see I/O or LAN menu buttons: these allow you to see the IP address given to your instrument. You can often tell if your instrument is on your LAN by whether it has a sensible address (many company LANs use IPs like e.g. 10.0.0.xx)
    3. RIGOL instruments are factory default set to acquire an IP address automatically if the LAN allows this. But check this setting has not been set to manual IP.
    4. If all else fails try manually entering the IP address you find in your instrument into UltraSigma's LAN window, and click to test. After success you can Add it.
  7. FINALLY PLEASE REMEMBER that some RIGOL software examples and software only function fully over USB connection - please check each software item, its install procedure and remember that some example VBA code is not supported but is provided ex-gratia for use as helpful examples only.


Was this article helpful?

Comments:
 

Related Articles
 > Is there an attenuator built-in on RIGOL's DSA815?
 > Is there an attenuator built-in on RIGOL's DSA1030?
 > Are there any independent reviews of RIGOL Spectrum Analysers like DSA815 in the UK?
 > How do I add a horizontal Display Line to my DSA screen?
 > How to reduce or lower noise floor? (DSA815 and DSA1030)
 > How to get the specified DANL of -135dBm? (typ, +6dB f/GHz)
 > How do I check my DSA is working properly?
 > How do radio amateurs use RIGOL's DSA815? And for what kinds of applications?
 > I just received mine… how can I tell if it's working OK?
 > What is the default password for DS2000 LXI settings pages
 > Can I get help on using complex functions of my instrument?
 > Can I get help with programming my instrument?
 > Will I get a UK phone number for the team who sold to me?
 > How do I achieve the lowest DANL with my spectrum analyser?
 > How to measure an RF Amplifier using a DSA-800 Series Spectrum Analyzer
 > Which oscilloscope probe is best for my application
 > EMC Precompliance: Testing on a budget
 > How do I measure an RF Bandpass filter
 > Is logging software included with RIGOL DM-series multimeters? What rate does it capture my readings to PC?
 > After receiving my instrument(s), what should I do with my RIGOL Warranty Card?
 > How can I use Ultra Sigma to grab data from my RIGOL Scope? E.g. CSV file for viewing in Excel?
 > Can I get Rigol firmware updates?
 > What file formats does RIGOL use for storage of waveforms etc? What is the different between Trace and Waveform?
 > When installing Ultra Sigma I get a message PC telling me to install NIVISA / VISA Runtime engine. What am i doing wrong?
 > What about RIGOL battery and portable use? Can you run RIGOL Scopes and Spectrum Analysers from Battery or portable UPS Power Supplies?
 > RIGOL scope has a message on screen saying WAIT (in green). All channels ON but I see no signal being displayed. Is this effect to do with triggering?
 > RIGOL DG4062 Wave generator simulates heartbeat, for life-saving pacemaker medical technology... with help of RIGOL-UK's Team Telonic Instruments Ltd.
 > USB stick / flash drive / memory sticks must fully compliant with USB2.0* standard compliant w/Win7 - Info on good sticks, esp. earlier models:
 > X-Y Display mode on Scopes - additional features with RIGOL DS1000Z-series oscilloscope (DS1074, DS1074Z-S, DS1104Z, DS1104Z-S)
 > RIGOL 3GHz Spectrum Analyser - Applications insights from RIGOL-UK's customers.
 > Getting started with Rigol PC Software Tools
 > AMK: What do you get with the DSA Advanced Measurement Kit ? (DSA1000-AMK)
 > test
 > How do i measure an RF Attenuator?
 > Using a Rigol product key to generate a Rigol software licence code.
 > Rigol PC Software Summary
 > Rigol PC Software Versions
 > Can I get IVI drivers for my Rigol test equipment?