Tekbox TBMR-110M EMI Test Receiver / Analyser DC-110 MHZ

£6011.00 (£7213.20 inc. VAT) (£7,213.20 inc VAT)

Available on back-order, delivery normally 1 - 2 weeks

Availability: Stock models delivered next working day (UK only) for orders placed before 16:30 (Mon - Fri)

SKU: TBMR-110M Categories: , Brand:

Description


Tekbox TBMR-110M EMI Test Receiver / Analyser DC-110 MHZ

To comply with international EMC standards, manufacturers must use specific measurement methods and equipment to ensure that a product’s electromagnetic emissions remain within legal limits. The TBMR-110M EMI Analyser is specifically engineered to handle these conducted emission measurements, offering a high-performance solution for modern engineering needs.

Because the device is both affordable and highly versatile, it serves as an ideal tool for engineers conducting pre-compliance testing during the product development stage. Identifying potential issues early on saves significant time and prevents costly redesigns later in the process.

Beyond the design phase, the analyser’s user-friendly interface makes it a practical choice for importers of electronic goods. It allows them to perform regular quality checks on their stock to ensure suppliers are maintaining consistent EMC standards. By bringing this capability in-house, businesses can verify compliance and quality control without the recurring expense of outsourcing to external test laboratories.

With its blend of high accuracy, versatility, and rapid measurement speeds, the TBMR-110M provides a professional-grade testing environment that is accessible to both developers and distributors alike.

Product Videos

Documentation

ParameterDescriptionValue/RangeRemark
Operating voltageMains voltage range100–120 VAC / 200–240 VAC, 50–60 HzMains voltage selection switch
Operating temperature0 °C – 40 °C
Storage temperature−20 °C – 60 °C
Frequency rangeOscilloscopeDC – 110 MHzTrue DC coupled
Spectrum analyser1 Hz – 110 MHzMax. 0 V DC
EMI analyser1 Hz – 110 MHzMax. 0 V DC
Reference frequency accuracyInitial accuracy after 30 minutes of warm-up±10 ppm
RF input connector50 Ohm, Type-N
RF input VSWR< 1 : 1.1510 … 30 dB att.
Maximum RF input levelAttenuation/gain dependent+30 dBm / 137 dBµV20 dB / 30 dB att.
Negative att. + gain+15 dBm / 122 dBµV / 1.25 V0 … −30 dB att.
Input RF attenuator0 – 30 dB in 10 dB steps
Input LNA0 – 30 dB in 0 dB steps
Amplitude accuracyDC – 110 MHzBetter ±0.8 dBat 18 °C – 28 °C
Noise (DANL)f = 10 Hz−132 dBm typ.RBW = 1 Hz
f = 100 Hz−144 dBm typ.RBW = 1 Hz
f = 1 kHz−149 dBm typ.RBW = 1 Hz
f = 10 kHz−156 dBm typ.RBW = 1 Hz
f = 100 kHz−160 dBm typ.RBW = 1 Hz
Intercept pointsIntercept point 2 (f = 10 MHz)+50 dBm typ.ATT = 0 dB
Intercept point 3 (f₁ = 32 MHz, f₂ = 33 MHz)+43 dBm typ.ATT = 30 dB
−6 dBm typ.ATT = −30 dB
Resolution bandwidth0.1 Hz – 3.5 MHzArbitrary
Video bandwidth0.1 Hz – 3.5 MHzArbitrary
Pre-selector filter bank7 bands + bypass6th-order band-pass
Sampling rate250 MSPS, 14-bit
DetectorRMS, pos./neg. peak, average, quasi peak, CISPR average, CISPR RMSAccording to CISPR 16-1-1 and MIL Std. 461
ProcessingSweep, STFFT, parallel sweep
Tracking generator frequency stability±25 ppm
Tracking generator amplitude stabilityDC – 100 MHzBetter ±0.5 dB
Tracking generator amplitude rangeLevel −30 dBm−50 dBm to 0 dBm
100 MHz – 110 MHz−50 dBm to −10 dBm
Dimensions/weight33 × 38 × 12 cm; 5.2 kg